Racadm command line reference guide for idrac9

The technology allows administrators to deploy, monitor, manage, configure, update, troubleshoot and remediate Dell servers from any location, and without the use of agents. It accomplishes this regardless of operating system or hypervisor presence or state.

Key Features. For information on the features available for a license, see Managing Licenses.

racadm command line reference guide for idrac9

For more information, see Generating Tech Support Report. Securing access to critical network resources is a priority.

The two-factor authentication is based on the physical smart card and the smart card PIN. It is recommended to use this, but it is disabled by default.

New In This Release. The contents of this User's Guide enable you to perform the tasks by using:. Supported Web Browsers.

Managing Licenses.

Only licensed features are available in the interfaces that allow you to configure or use iDRAC. This is optional on. Types of Licenses. Evaluation licenses are duration based, and the timer runs when power is applied to the system.

Acquiring Licenses. Click this link to open the licensing Self-Service Portal on the internet. Currently, you can use the License Self-Service Portal to retrieve licenses that were purchased with the server. You must contact the sales representative or technical support to buy a new or upgrade license. For more information, see the online help for the self-service portal page. License Operations. Before you perform the license management tasks, make sure to acquire the licenses.

For more information, see the Overview and Feature Guide available at dell. NOTE: If you have purchased a system with all the licenses pre-installed, then license management is not required. The license is imported if it passes the validation checks. NOTE: For a few features, a system restart is required to enable the features. The file name and format of the exported license is.

Extract SupportAssist Logs Using iDRAC 9

After the license is deleted, it is not stored in iDRAC and the base product functions are enabled. For more information, see the Internet.

For one-to-many license deployment, you can use Dell License Manager. For more information, see the. For more information about this utility and to download this tool, click here. The following table provides the list of license operations available based on the license state or condition.

The Licensing page displays the licenses that are associated to devices, or the licenses that are installed but the device is not present in the system. The following table provides the iDRAC8 features that are enabled based on the license purchased. NOTE: Using more than one interface at the same time may generate unexpected results.

Data streams. Interface or Protocol.Loading, Please wait. Notes, cautions, and warnings. New in this release. Using The Autocomplete Feature.

Lifecycle Controller Log. Other Documents You May Need. Accessing documents from Dell support site. Contacting Dell. Displayable Characters. BackplaneBusMode Read Only. ChassisInfraPower Read. ChassisPowerCap Read. ChassisManagementMonitoring Read or Write. ChassisModel Read Only. ChassisName Read Only. ChassisServiceTag Read Only. Configuration Read or Write. CurrentDisplay Read Only. QualifierTemp Read or Write.

QualifierWatt Read or Write. UserDefinedString Read or Write. Aisle Read or Write. DataCenter Read or Write. DeviceSize Read Only. Name Read or Write.Loading, Please wait. Notes, cautions, and warnings. New in this release. Using autocomplete feature. Lifecycle Controller Log. Proxy parameters. Other Documents You May Need. Accessing documents from Dell support site. Contacting Dell. Displayable Characters. CostCenter Read or Write. Expensed Read or Write.

InstallDate Read or Write. PONumber Read or Write. PurchaseCost Read or Write. PurchaseDate Read or Write. Vendor Read Only. WayBill Read or Write. WhoSigned Read or Write. BackplaneBusMode Read Only. ChassisInfraPower Read. ChassisPowerCap Read.

ChassisManagementMonitoring Read or Write. ChassisType Read or Write. ConnectionState Read or Write. FirmwareVersion Read or Write. ChassisModel Read Only. ChassisName Read Only.

ChassisServiceTag Read Only. Label Read or Write. Value Read or Write. Duration Read or Write. DurationUnit Read or Write. Method Read or Write.

How to configure a Dell iDRAC card using the Racadm command line tool

Percentage Read or Write. Cost Read or Write. EndDate Read or Write. Provider Read or Write. StartDate Read or Write.Much like with HP's ILOM there is a command line utility provided in this case racadm in order to interact with it, fetching and setting config. This page is a basic cheatsheet of the commands which can be used with it, all should be run from a shell. However, if you prefer to use the interactive mode, run racadm on it's own, and then just omit racadm from the command.

The benefit of that approach, is that from approximately racadm7 you'll have tab-completion available to help you create commands. This site should work without Javascript enabled. If you find something doesn't, please Contact Me. Language BASH. Much like with HP's ILOM there is a command line utility provided in this case racadm in order to interact with it, fetching and setting config This page is a basic cheatsheet of the commands which can be used with it, all should be run from a shell.

Keywords racadmbmcDellidraccommandscheat sheetclihowto. Detect when Enter is pressed within an Input Element Javascript. Select contents of element and its children and copy to clipboard Javascript. Intercept Console Messages in Javascript Javascript.RACADM commands allow you to view managed system information, perform power operations on the managed system, perform firmware updatesconfigure settings and more.

See the links to the RACADM documentation at the end of this article for a complete listing of features for your product version. Here is the content of sbin directory:. You may need to log out and log back in to reset the PATH environment variable to include this location. Then run. Accept the license agreement and select option 5 - Remote Access Core Component from the menu.

See your user's guide for connecting via these methods. Commands can then be entered from this prompt without the "racadm" prefix.

Then execute:. So, to power off and back on your server, you just type racadm serveraction powercycle. Making racadm reboot a server does not play nicely with reboot aware system automation. It only works well for ad-hoc configurations. A mass configuration tool should not just work well for ad-hoc execution. From "racadm help set":. The parameters are "Graceful" and "Forced" for graceful and forced shutdown respectively. If this parameter is not specified, graceful shutdown is taken as the default.

Nikolai Bezroukov. This document is an industrial compilation designed and created exclusively for educational use and is distributed under the Softpanorama Content License. Original materials copyright belong to respective owners. Quotes are made for educational purposes only in compliance with the fair use doctrine. We are making such material available to advance understanding of computer science, IT technology, economic, scientific, and social issues.

We believe this constitutes a 'fair use' of any such copyrighted material as provided by section of the US Copyright Law according to which such material can be distributed without profit exclusively for research and educational purposes. Grammar and spelling errors should be expected.

RACADM Command Line Interface for DRAC on Linux

The site contain some broken links as it develops like a living tree The statements, views and opinions presented on this web page are those of the author or referenced source and are not endorsed by, nor do they necessarily reflect, the opinions of the author present and former employers, SDNP or any other organization the author may be associated with.

We do not warrant the correctness of the information provided or its fitness for any purpose. The site uses AdSense so you need to be aware of Google privacy policy. You you do not want to be tracked by Google please disable Javascript for this site. This site is perfectly usable without Javascript. Unix Administration.

Red Hat. Toxic Managers.Recommend Documents. Command Reference Guide. Chapter Commands for Status Monitoring and Statistics Event Management System Extreme Link Command Reference. OpenBoot Command Reference Manual. Gretl Command Reference. Places the standard input into the file. Searches in the current directory represented by.

DOS Command Reference. IP Command Reference. For example, all TEST subcommands are AutoCAD reference command list. Command line tools. Command Line Interface Reference Guide. Version 7. Common Privileged Executive Mode Commands. Getting Help. Command Control Interface. User and Reference Guide. Hitachi Virtual Storage Platform G Chassis Management Controller Version 1. Page 2. Notes, Cautions, and Warnings. A00 Contents 1 Introduction The utility runs on the management station and the managed system.

Use: if the iDRAC port number is not the default port If the -u option is used, the -p option must be used, and the -i option interactive is not allowed. If the -p option is used, the -i option is not allowed. RACADM stops the execution of the command with an error message if it detects an invalid certificate. Along with this Reference Guide, you can access the following guides available at dell.

This document is available online at dell. For additional regulatory information, see the Regulatory Compliance home page at www. Warranty information may be included within this document or as a separate document. For more information on the system, scan the Quick Resource Locator QRL available on your system and the system setup placemat that shipped with your system.

Download the QRL application from your mobile platform to enable the application on your mobile device.RAC Configuration File. Property Database.

racadm command line reference guide for idrac9

The racadm command-line utility provides a scriptable interface that allows you to locally or remotely configure your remote access controller RAC. Using the racadm command, you can enter subcommands to configure RAC properties. When you enter racadm subcommands, the racadm utility sets or retrieves object property values in the RAC properties database. You can also use the racadm utility to write scripts that will automatically configure multiple RACs.

For example, when configuring in batch mode, a series of calls to the racadm utility can perform actions such as upgrading RAC firmware, setting a property to a specific value, and reading the configuration of the RAC. All command switches are case-sensitive. Without options, racadm executes the help command, which displays a list of available tests and a one-line description of each. The racadm utility provides a remote capability option -r that allows you to connect to the managed system and execute racadm subcommands from a remote console or management station.

You only need the IP address of the managed system. Specifies the user name that is used to authenticate the command transaction. If not specified, the default user name "racadmusr" is used. If the -u option is used, the -p option must be used, and the -i option interactive is not allowed.

Specifies the password used to authenticate the command transaction.

racadm command line reference guide for idrac9

If the -p option is used, the -i option is not allowed. If you use the -r option, you must also use the -u and -p options to configure the RAC to accept racadm commands. Using the -r option without the previously listed options will result in a command failure. Both of these message types are written to the file name log. Sets time, managed system name, operating system name, and type from the managed system to the RAC. When using racadm commands and subcommands, you may encounter one or more of the following errors:.

If you are running racadm remotely, transport error messages may indicate network communication problems or that the management station is unable to communicate with the RAC. The configuration file is a simple text file that allows the user to build a configuration file similar to an.

racadm command line reference guide for idrac9

You may use any file name, and the file does not require a. Errors are flagged with the line number in which the error was detected, and a simple message explains the problem. The entire file is parsed for correctness, and all errors are displayed. Writes are not performed to the RAC if an error is found in the. The user must correct all errors before any configuration can take place. The -c option may be used in the config subcommand, which verifies syntax only and does not perform writes to the RAC.

The parser reads in all of the indexes from the RAC for that group.


thoughts on “Racadm command line reference guide for idrac9

Leave a Reply

Your email address will not be published. Required fields are marked *